久久99精品视频一区,把老师下面日出水视频,国产成人欧美日韩在线电影,外国特级AAAA免费

您好, 歡迎來到化工儀器網(wǎng)

| 注冊| 產(chǎn)品展廳| 收藏該商鋪

15601682291

business

首頁   >>   供求商機

TNT843
  • TNT843
舉報

貨物所在地:上海上海市

更新時間:2025-02-25 16:07:45

瀏覽次數(shù):147

在線詢價收藏產(chǎn)品

( 聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝!)

For determination of Reactive (ortho) and Total Phosphorus (phosphate) by the Ascorbic Acid method, using TNTplus vials. Hach Methods 10209 (reactive) and 10210 (total). Low Range: 0.05-1.50 mg/L PO4-

Reduce Errors with Bar-coded Vials and RFID

A unique barcode label on each Hach TNTplus Vial Chemistry is automatically read by the spectrophotometer when used with Hach’s DR 6000™ UV-VIS Spectrophotometer or DR 3900™ Benchtop Spectrophotometer to identify the appropriate method and take the measurement. While increasing ease-of-use and speed of analysis, errors are significantly reduced. In addition, the user will receive a notification if shelf life of a TNTplus test has been expired. The RFID tag on each TNTplus box contains the lot specific Certificate of Analysis which can be read out with the DR 6000™ or DR 3900™ spectrophotometer.

No Reagent Blank Necessary

The high quality of TNTplus vials, tight reagent production controls, 10-fold absorbance readings averaged for results determination, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!

Innovative Vial and Reagent Delivery

TNTplus vials use innovative DosiCaps that are easier to use than powder pillows or liquid reagents. There’s no risk of spillage, no safety risk, or risk of contamination with DosiCaps because the reagents are compley contained within the vial cap. The glassware used assures the best precision and the vials have a flat bottom so they can stand on their own.

Helpful package design

Packages of TNTplus vials are color-coded for fast and easy parameter and range recognition for the exact test you need. Step-by-step illustrated test methods are printed on the box for quick reference. Instructions in simple multiple language formats, included in each carton, facilitates use by a diverse labor force.

Specifications

# Tests:25

Digestion Required:Yes for Total

EPA compliant:Yes

Instrument:DR 6000, DR 3900,
DR 2800, DR 1900

Method:10209

Method Name:Ascorbic Acid

Platform :TNT+

Range:to mg/L P (0.15 - 4.5 mg/L PO?)

Ranges:0.05 to 1.5 mg/L P (0.15 - 4.5 mg/L PO?)